IPS | Three Phase Transformer-Less

.

Three Phase Transformer-Less


Power rang :(10-500kVA) pf : 0,9
THREE PHASE DSP IGBT CONTROL
UNINTERRUPTIBLE POWER SUPPLY 10-500 kVA
Cold Start
High Input Power Factor
High efficiency up to 94%
External REPO switch input
10 years spare parts support
IGBT DSP Technology with Galvanic Isolation Transformer at output DSP Control
NEW !… DSP+IGBT Rectifier Technology

  • Low input current total harmonic distortion (THD)
  • Static and maintenance bypass switch
  • Output and by-pass short circuit and overload protection
  • 192 events memory (192 events 4500 alarms)
  • Clock and calender (battery supported)
  • Automatic battery test, remaining battery time indicator
  • Temperature compansiated charge system
  • Regenerative backfeed function
  • 2 RS232 serial port and 12 dry contact outputs
  • 3 DSP controlled modular structure
  • Optional Graphical and touch panel
  • CE ,ISO9001, ISO14001, GOST certification
ECHNICIAL SPECIFICATIONS
Nominal power (kVA) 10 – 500
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, – 25% optional)
Frequency 50Hz / 60Hz, ± 10%
Power factor (at100% load) ≥ 0.99
THDI (*) ≤ %3
By-Pass Voltage 380/400 VAC 3 Phase + N, ± 10%
Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 9 – 450
Power factor 0,9
Voltage 380/400 VAC 3P + N, ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency Tolerance Line synchronized: ± 2% (adjustable) / Free running: ± 0,1%
Efficiency (at 100% load) up to 94%
Output current crest factor 3:1
Overload Protection 100% – 125% load: 10 min, 125% – 150% load: 1 min, – > 150% load: by pass
Other Protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
THD ≤ 2% (at 100% linear load)
BATTERIES
Type VRLA AGM / GEL / NiCd
Battery Number ± 360 VDC (2X30 batteries)
Float charging voltage ± 410 VDC
Float / End of dischg voltage ± 300 VDC
Battery Housing External
Battery ambient temp 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic Testing Standard every 72 hours (adjustable)
GENEL
Standards EN62040-1 , EN62040-2, EN62040-3
User Interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
INDICATORS P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset Kit Standard (programmable)
Software Standard T-Mon UPS Management software (3 clients + 1 server management)
Alarm Logging Standard: with time & date 512 events
Protections Power module over-temperature, Overcurrent, Temperature high alarm
Temperature Range 0ºC – 40ºC
Protection class IP20
Relative humidity 90% max. (non-condensing)
Altitude < 1000m above sea level
Noise level < 57 dBA
OPTIONS
Input / Output voltage Please ask
Transformer Transformer less (default ) – Galvanic isolation transformer at input (optional)
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Comm. adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer
Parallel Operation Up to 8 units